Passive fire protection products, matched to your drawings.
Every line below is drawn from tested, internationally listed system ranges. Send a penetration schedule, steel list or duct route and we return a system schedule with quantities.
Flexible foil-faced blanket systems that maintain the integrity and insulation of kitchen extract, smoke and ventilation ducts without building a rated shaft around them.
Kitchen extractSmoke ductsEN 1366-1 / -8
02
Mineral Wool Fibre
High-density stone wool batts and slabs for compartment walls, floor voids, cavity barriers and firestop backing, non-combustible and dimensionally stable at temperature.
Compartment wallsCavity barriersNon-combustible
03
Fire Retardant Paint
Thin-film and epoxy intumescent coatings that expand under fire to insulate structural steel, specified by section factor to the required period.
Structural steelUp to 240 minUL 263
04
Firestop Systems
Sealants, wraps, collars, mortars, pillows and putty pads for MEP penetrations of every size, from single services through to mixed-service openings.
Pipes & cablesMixed servicesUL 1479 / ASTM E814
05
Fire Rated Gaskets
Intumescent gaskets, strips and smoke seals for door assemblies, dampers, glazing frames and equipment openings that must stay sealed in fire.
Doors & dampersSmoke sealsIntumescent
06
Expansion Joint Systems
IRated joint barriers for floors, walls and facade interfaces that keep their seal through the structure’s designed movement.
Movement jointsFloor & wallUL 2079
07
Compartmentation Boards
Calcium silicate and gypsum board systems for riser shafts, duct enclosures, rated barriers and steel encasement where a board solution is specified.
Riser shaftsDuct enclosuresSteel encasement
08
Marine Fire Class Insulation
Class-approved A- and H-class insulation for bulkheads, decks and marine ducting, supplied with the approved fixing details.
A-60 / H-120Bulkheads & decksIMO FTP Code
09
Pins & Washers
Insulation pins, cup washers and clips — weld, adhesive and mechanical — engineered to retain wrap and insulation for the full rated life.
Wrap retentionSmoke ductsStainless options
10
Anchor Fasteners
Load-rated mechanical anchors for board, barrier and support systems in concrete and masonry, selected against pull-out and fire performance data.
Concrete & masonryLoad ratedBoard systems
Test standards
Systems supplied are party tested & listed to
A rating belongs to a tested configuration, not to a product. We quote the system, the listing it sits under, and the conditions it was tested for.
Fire tests of penetration firestops: F, T and L ratings
UL 2079
Fire resistance of building joint systems
UL 263
Fire tests of building construction and materials
FM 4991
Approval standard for firestop contractors
EN 1366
Fire resistance tests for service installations
BS 476
Fire tests on building materials and structures
ASTM E814
Test method for penetration firestop systems
IMO FTP
IMO Fire Test Procedures Code, marine class
Send the drawing. We'll send the system.
Penetration schedules, steel sections, duct routes, joint details. Our experts return a compliant selection, quantities and a budget within one working day.